In this work, we investigated the ability of an electrochemical sensor to recognize Cannabis sativa L. samples with different total content of Δ9-tetrahydrocannabinol (Δ9-THC), determined by the levels of the psychoactive cannabinoid and of its biosynthetic precursor Δ9-tetrahydrocannabinolic acid (Δ9-THCA), using a multivariate approach. The voltammetric responses recorded with screen-printed electrodes modified with carbon black reflected the compositional differences from the different samples, in terms of cannabinoids of the vegetal material. PLS-DA models allowed for the correct classification of most C. sativa samples into the classes of legal and illegal samples according to total Δ9-THC content, based on threshold limits defined by the EU/US (0.3 % w/w) and Italian (0.6 % w/w) regulations. Satisfactory results were achieved in both cases, obtaining classification efficiency values in prediction of the external test set equal to 85 % and 100 % for the EU/US and Italian thresholds, respectively. The obtained results suggest the possibility to consider the proposed method as a starting point for the implementation of an automated device for rapid prescreening of total Δ9-THC content directly on site.
Electrochemical sensors for fast classification of different Cannabis sativa L. samples according to total Δ9-tetrahydrocannabinol content
Zanardi, Chiara;
2025-01-01
Abstract
In this work, we investigated the ability of an electrochemical sensor to recognize Cannabis sativa L. samples with different total content of Δ9-tetrahydrocannabinol (Δ9-THC), determined by the levels of the psychoactive cannabinoid and of its biosynthetic precursor Δ9-tetrahydrocannabinolic acid (Δ9-THCA), using a multivariate approach. The voltammetric responses recorded with screen-printed electrodes modified with carbon black reflected the compositional differences from the different samples, in terms of cannabinoids of the vegetal material. PLS-DA models allowed for the correct classification of most C. sativa samples into the classes of legal and illegal samples according to total Δ9-THC content, based on threshold limits defined by the EU/US (0.3 % w/w) and Italian (0.6 % w/w) regulations. Satisfactory results were achieved in both cases, obtaining classification efficiency values in prediction of the external test set equal to 85 % and 100 % for the EU/US and Italian thresholds, respectively. The obtained results suggest the possibility to consider the proposed method as a starting point for the implementation of an automated device for rapid prescreening of total Δ9-THC content directly on site.| File | Dimensione | Formato | |
|---|---|---|---|
|
107-THC_Talanta2024.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Accesso libero (no vincoli)
Dimensione
4.8 MB
Formato
Adobe PDF
|
4.8 MB | Adobe PDF | Visualizza/Apri |
I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



