The large size of a glazed component allows greater access to natural light inside and a wider view of the outdoors while protecting the inside from extreme weather conditions. However, glazed components make buildings energy inefficient compared to opaque components if not designed suitably, and sometimes they create glare discomforts too. In order to protect against excessive natural light and direct sunlight and for privacy, dynamic shading devices are integrated into the glazed façade. In this study, the impact of various glazing and shading design parameters has been investigated by performing uncertainty and sensitivity analyses. The uncertainty analysis indicates that the variance coefficients for the source energy use, lighting energy use, useful daylight illuminance (UDI), and shade-deployed time fraction are in the ranges of 15.04–30.47, 39.05–45.06, 40.57–49.92, and 19.35–52%, respectively. The dispersion in the energy and indoor visual performance is evident by the large variation in the source energy consumption and UDI (500–2000), which vary in the ranges of 250–450 kWh/(m2-year) and 5–90%. Furthermore, a sensitivity analysis identified the window-to-wall ratio (WWR), aspect ratio (ASR), glazing type (Gt), absorptance of the wall (Aw), and shade transmittance (ST) as major influences of the parameters. Each of the identified parameters has a different proportionate impact depending on the façade orientation and performance parameters.

Sensitivity Analysis for Decisive Design Parameters for Energy and Indoor Visual Performances of a Glazed Façade Office Building

Thapa S.;
2022-01-01

Abstract

The large size of a glazed component allows greater access to natural light inside and a wider view of the outdoors while protecting the inside from extreme weather conditions. However, glazed components make buildings energy inefficient compared to opaque components if not designed suitably, and sometimes they create glare discomforts too. In order to protect against excessive natural light and direct sunlight and for privacy, dynamic shading devices are integrated into the glazed façade. In this study, the impact of various glazing and shading design parameters has been investigated by performing uncertainty and sensitivity analyses. The uncertainty analysis indicates that the variance coefficients for the source energy use, lighting energy use, useful daylight illuminance (UDI), and shade-deployed time fraction are in the ranges of 15.04–30.47, 39.05–45.06, 40.57–49.92, and 19.35–52%, respectively. The dispersion in the energy and indoor visual performance is evident by the large variation in the source energy consumption and UDI (500–2000), which vary in the ranges of 250–450 kWh/(m2-year) and 5–90%. Furthermore, a sensitivity analysis identified the window-to-wall ratio (WWR), aspect ratio (ASR), glazing type (Gt), absorptance of the wall (Aw), and shade transmittance (ST) as major influences of the parameters. Each of the identified parameters has a different proportionate impact depending on the façade orientation and performance parameters.
2022
14
File in questo prodotto:
File Dimensione Formato  
2022 Sensitivity Analysis of Glazed Facade Office Building.pdf

accesso aperto

Tipologia: Versione dell'editore
Licenza: Creative commons
Dimensione 6.18 MB
Formato Adobe PDF
6.18 MB Adobe PDF Visualizza/Apri

I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10278/5017143
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact