Procedures for the preparation and characterisation of ensembles of gold nanodisk electrodes (NEE) of 30nm diameter are presented, in particular focusing on improvements in the signal/background current ratios and detection limits with respect to the electrochemical oxidation of iodide and its analytical determination in water samples. At NEEs iodide undergoes a quasi-reversible diffusion controlled oxidation with a slight shift in E1/2 values and slightly higher peak to peak separation with respect to conventional gold disk electrodes. The double layer charging current at the NEE is significantly lower than at conventional electrodes so that the detection limit (DL) by cyclic voltammetry with NEEs in tap water is significantly lower than DL at the Au-disk millimetre-sized electrode (DL 0.3 μM at NEE vs. 4 μM for Au-disk). Finally, it is shown that NEEs in combination with square wave voltammetry can be applied for the direct determination of iodide in water samples from the lagoon of Venice, with a detection limit of 0.10 μM. © 2010 Taylor & Francis.
Nanoelectrode ensembles for the direct voltammetric determination of trace iodide in water
UGO, Paolo;MORETTO, Ligia Maria;SILVESTRINI, MORENA;
2010-01-01
Abstract
Procedures for the preparation and characterisation of ensembles of gold nanodisk electrodes (NEE) of 30nm diameter are presented, in particular focusing on improvements in the signal/background current ratios and detection limits with respect to the electrochemical oxidation of iodide and its analytical determination in water samples. At NEEs iodide undergoes a quasi-reversible diffusion controlled oxidation with a slight shift in E1/2 values and slightly higher peak to peak separation with respect to conventional gold disk electrodes. The double layer charging current at the NEE is significantly lower than at conventional electrodes so that the detection limit (DL) by cyclic voltammetry with NEEs in tap water is significantly lower than DL at the Au-disk millimetre-sized electrode (DL 0.3 μM at NEE vs. 4 μM for Au-disk). Finally, it is shown that NEEs in combination with square wave voltammetry can be applied for the direct determination of iodide in water samples from the lagoon of Venice, with a detection limit of 0.10 μM. © 2010 Taylor & Francis.File | Dimensione | Formato | |
---|---|---|---|
2010-IntJEnvironAnalChem.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Accesso gratuito (solo visione)
Dimensione
3.99 MB
Formato
Adobe PDF
|
3.99 MB | Adobe PDF | Visualizza/Apri |
I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.