Thin alumina films coated platinum substrates (Pt/Al2O3), prepared by r.f. magnetron sputtering, wereused as working electrodes for voltammetric measurements. The thickness of the alumina layers var-ied between 50 and 1000 nm. For comparison, measurements were also performed with a platinummicrodisk 12.5 µm radius (Ptdisk). Several electroactive species either charged or uncharged, dissolved inaqueous, non-aqueous and micellar media were probed by the Pt/Al2O3and Ptdiskelectrode systems. Inall cases, sigmoid well-shaped cyclic voltammograms were recoded, typical for microelectrodes work-ing under steady-state. It was established that the Pt/Al2O3samples behaved as ensembles of recessednanoelectrodes, wired in parallel, each nanoelectrode sufficiently far apart, such that no overlap of indi-vidual radial diffusion profiles occurred. The recessed nanoelectrodes were due to defects or pinholesformed during the alumina deposition. The analysis of the steady-state limiting currents, obtained atthe different electrode systems, allowed verifying that no pore size effect was evident for either chargedor uncharged species, whose average hydrodynamic radii were lower than 1 nm. Size exclusion effectswere instead observed at the thickest alumina film, using ferrocene dissolved in the hydrophobic coreof sodium dodecylsulphate micelles, whose hydrodynamic radius is about 2 nm. The Pt/Al2O3systemswere also used as substrates for electroplating. In this way, ensembles of platinum black microelectrodeswere prepared and employed for the voltammetric sensing of hydrogen peroxide.
Platinum/Alumina thin films prepared by r.f. magnetron sputtering as platforms in voltammetric sensing
BATTISTEL, DARIO;DANIELE, Salvatore;BATTAGLIN, Giancarlo
2014-01-01
Abstract
Thin alumina films coated platinum substrates (Pt/Al2O3), prepared by r.f. magnetron sputtering, wereused as working electrodes for voltammetric measurements. The thickness of the alumina layers var-ied between 50 and 1000 nm. For comparison, measurements were also performed with a platinummicrodisk 12.5 µm radius (Ptdisk). Several electroactive species either charged or uncharged, dissolved inaqueous, non-aqueous and micellar media were probed by the Pt/Al2O3and Ptdiskelectrode systems. Inall cases, sigmoid well-shaped cyclic voltammograms were recoded, typical for microelectrodes work-ing under steady-state. It was established that the Pt/Al2O3samples behaved as ensembles of recessednanoelectrodes, wired in parallel, each nanoelectrode sufficiently far apart, such that no overlap of indi-vidual radial diffusion profiles occurred. The recessed nanoelectrodes were due to defects or pinholesformed during the alumina deposition. The analysis of the steady-state limiting currents, obtained atthe different electrode systems, allowed verifying that no pore size effect was evident for either chargedor uncharged species, whose average hydrodynamic radii were lower than 1 nm. Size exclusion effectswere instead observed at the thickest alumina film, using ferrocene dissolved in the hydrophobic coreof sodium dodecylsulphate micelles, whose hydrodynamic radius is about 2 nm. The Pt/Al2O3systemswere also used as substrates for electroplating. In this way, ensembles of platinum black microelectrodeswere prepared and employed for the voltammetric sensing of hydrogen peroxide.File | Dimensione | Formato | |
---|---|---|---|
sensors and actuators B.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Licenza non definita
Dimensione
1.74 MB
Formato
Adobe PDF
|
1.74 MB | Adobe PDF | Visualizza/Apri |
I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.