We demonstrate the use of a silicon detector based on a DEPFET device, with sub-electron readout noise (0.6 e- ENC). The so-called repetitive non-destructive readout (RNDR) detector was realised by putting two single DEPFETs next to each other, and connecting their charge storing region by an additional gate. By every transfer from gate 1 to 2 and vice versa the signal charge can be measured non-destructively. By taking the average value of a large number (n) of these measurements the serial noise is reduced by 1 / sqrt(n). This way of readout does not only reduce the white noise, but also averages out the 1 / f noise. Because the whole readout time is n times longer than the time for one readout, the device is interesting for low-noise and low-flux applications. The main advantage of such a detector is the ability to reduce the influence of 1 / f noise to the readout noise. The theoretically and experimentally achievable resolution for different operating parameters (leakage current, readout noise, number and duration of readouts) were investigated by Monte-Carlo simulations and measured on single pixel RNDR devices. © 2006 Elsevier B.V. All rights reserved.

Sub-electron noise measurements on repetitive non-destructive readout devices

Porro M.;
2006-01-01

Abstract

We demonstrate the use of a silicon detector based on a DEPFET device, with sub-electron readout noise (0.6 e- ENC). The so-called repetitive non-destructive readout (RNDR) detector was realised by putting two single DEPFETs next to each other, and connecting their charge storing region by an additional gate. By every transfer from gate 1 to 2 and vice versa the signal charge can be measured non-destructively. By taking the average value of a large number (n) of these measurements the serial noise is reduced by 1 / sqrt(n). This way of readout does not only reduce the white noise, but also averages out the 1 / f noise. Because the whole readout time is n times longer than the time for one readout, the device is interesting for low-noise and low-flux applications. The main advantage of such a detector is the ability to reduce the influence of 1 / f noise to the readout noise. The theoretically and experimentally achievable resolution for different operating parameters (leakage current, readout noise, number and duration of readouts) were investigated by Monte-Carlo simulations and measured on single pixel RNDR devices. © 2006 Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10278/3755494
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact