An office equipped with personal footwarmers was maintained at cooler-than-normal indoor temperatures in the winter, producing great energy savings. The occupants' thermal comfort was not affected. The footwarmers provide individual heating control over a segment of the body that most strongly influences comfort perception when one is cool overall. If cooler ambient indoor temperatures could be made comfortable, savings in central heating energy would be possible. During a six-month winter period in Berkeley California, knowledge workers with low-energy footwarmers experienced a lowering of room heating set point from 21.1 degrees C (70 degrees F) to 18.9 degrees C (66 degrees F). Surveys showed equal thermal comfort in the original 'higher heating setpoint no-footwarmer' condition and the 'lower heating set point plus occupant-controllable footwarmer' condition. Heating energy was closely monitored throughout. It dropped 38-75% depending on the setpoint reduction and outdoor conditions. The added plug load energy from the low-energy footwarmers was much less than the central heating energy saved by lowering the heating set point (3-21 W vs 500-700 W average power per occupant during occupied hours). A few subjects had ergonomic issues with the particular footwarmers used, so usage was not universal. Additional foot- and leg-warmer design options would help. (C) 2015 Elsevier B.V. All rights reserved.

Using footwarmers in offices for thermal comfort and energy savings

PASUT, Wilmer;
2015-01-01

Abstract

An office equipped with personal footwarmers was maintained at cooler-than-normal indoor temperatures in the winter, producing great energy savings. The occupants' thermal comfort was not affected. The footwarmers provide individual heating control over a segment of the body that most strongly influences comfort perception when one is cool overall. If cooler ambient indoor temperatures could be made comfortable, savings in central heating energy would be possible. During a six-month winter period in Berkeley California, knowledge workers with low-energy footwarmers experienced a lowering of room heating set point from 21.1 degrees C (70 degrees F) to 18.9 degrees C (66 degrees F). Surveys showed equal thermal comfort in the original 'higher heating setpoint no-footwarmer' condition and the 'lower heating set point plus occupant-controllable footwarmer' condition. Heating energy was closely monitored throughout. It dropped 38-75% depending on the setpoint reduction and outdoor conditions. The added plug load energy from the low-energy footwarmers was much less than the central heating energy saved by lowering the heating set point (3-21 W vs 500-700 W average power per occupant during occupied hours). A few subjects had ergonomic issues with the particular footwarmers used, so usage was not universal. Additional foot- and leg-warmer design options would help. (C) 2015 Elsevier B.V. All rights reserved.
2015
104
File in questo prodotto:
File Dimensione Formato  
2015_Using footwarmers in offices for thermal comfort and energy savings.pdf

non disponibili

Tipologia: Versione dell'editore
Licenza: Accesso chiuso-personale
Dimensione 3.52 MB
Formato Adobe PDF
3.52 MB Adobe PDF   Visualizza/Apri
2015_Using footwarmers in offices for thermal comfort and energy savings.pdf

accesso aperto

Descrizione: Documento disponibile presso biblioteca UC-Berkeley
Tipologia: Documento in Pre-print
Licenza: Accesso gratuito (solo visione)
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF Visualizza/Apri

I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10278/3709709
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 100
  • ???jsp.display-item.citation.isi??? 83
social impact