An interlaboratory comparison was performed to evaluate the analytical methods for quantification of anhydrosugars â levoglucosan, mannosan, galactosan â and biosugars â arabitol, glucose and mannitol â in atmospheric aerosol. The performance of 10 laboratories in Italy currently involved in such analyses was investigated on twenty-six PM (particulate matter) ambient filters, three synthetic PM filters and three aqueous standard solutions. An acceptable interlaboratory variability was found, determined as the mean relative standard deviation (RSD%) of the results from the participating laboratories, with the mean RSD% values ranging from 25% to 46% and decreasing with increasing sugar concentration. The investigated methods show good accuracy, evaluated as the percentage error (ε%) related to mean values, since method biases ranged within ±20% for most of the analytes measured in the different laboratories. The detailed investigation (ANOVA analysis at p < 0.05) of the contribution of each laboratory to the total variability and the measurement accuracy shows that comparable results are generated by the different methods, despite the great diversity in terms of extraction conditions, chromatographic separation - more recent LC (liquid chromatography) and EC (exchange chromatography) methods compared to more widespread GC (gas chromatography) - and detection systems, namely PAD (pulsed amperometric detection) or mass spectrometry.
Results of an interlaboratory comparison of analytical methods for quantification of anhydrosugars and biosugars in atmospheric aerosol
GAMBARO, Andrea;
2017-01-01
Abstract
An interlaboratory comparison was performed to evaluate the analytical methods for quantification of anhydrosugars â levoglucosan, mannosan, galactosan â and biosugars â arabitol, glucose and mannitol â in atmospheric aerosol. The performance of 10 laboratories in Italy currently involved in such analyses was investigated on twenty-six PM (particulate matter) ambient filters, three synthetic PM filters and three aqueous standard solutions. An acceptable interlaboratory variability was found, determined as the mean relative standard deviation (RSD%) of the results from the participating laboratories, with the mean RSD% values ranging from 25% to 46% and decreasing with increasing sugar concentration. The investigated methods show good accuracy, evaluated as the percentage error (ε%) related to mean values, since method biases ranged within ±20% for most of the analytes measured in the different laboratories. The detailed investigation (ANOVA analysis at p < 0.05) of the contribution of each laboratory to the total variability and the measurement accuracy shows that comparable results are generated by the different methods, despite the great diversity in terms of extraction conditions, chromatographic separation - more recent LC (liquid chromatography) and EC (exchange chromatography) methods compared to more widespread GC (gas chromatography) - and detection systems, namely PAD (pulsed amperometric detection) or mass spectrometry.File | Dimensione | Formato | |
---|---|---|---|
Chem 2017.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Accesso chiuso-personale
Dimensione
769.9 kB
Formato
Adobe PDF
|
769.9 kB | Adobe PDF | Visualizza/Apri |
manuscript_chem_preprint.docx
accesso aperto
Tipologia:
Documento in Pre-print
Licenza:
Accesso gratuito (solo visione)
Dimensione
862.5 kB
Formato
Microsoft Word XML
|
862.5 kB | Microsoft Word XML | Visualizza/Apri |
I documenti in ARCA sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.